Philips HP 50XM M1360b Fetal Monitor

Fetal / Maternal Monitor Philips Series 50 XM is designed to trained health professionals for use in the patient’s environment to monitor fetal and maternal condition before labor and delivery and During.

  • Fetal and maternal monitoring system fully integrated
  • For use with high-risk Patients Patients receiving anesthesia or labor and delivery During
  • Power requirements: Operating voltage 100-120 V (± 10%), 220 – 240 V (± 10%), line 50 to 60 Hz frequency, power consumption 60 VA max.
  • Dimensions and weight without transducers
    • Height 147 mm (5.8 inches)
    • Width 422mm (16.6in)
    • Depth 392mm (15.4in)
    • Weight 14.6kg (31.96lb

 

Description

  • Philips HP 50XM Specifications

    fetal Dispay

    • maternal non-invasive blood pressure
    • Heart rate range 50-240 bpm US, DECG 30 to 240 bpm, 240 bpm MHR 30 (not shown)
    • Toco outer range 0 to +127 relative units
    • IUP range -99 to +127 mmHg
    • Fetus SpO2 Range 0 – 99%
    • Precision pressure transducer 15 ° C to 25 ° C ± 3 mmHg, 10 ° C to 35 ° C ± 3 mmHg (± 0,6% of reading), 0 ° C to 55 ° C ± 3 mmHg (± 1, 7% of the reading)
    • Systolic measurement ranges 30 to 270 mmHg Diastolic 10-245 mmHg
    • Typically less than inflator cuff 10 seconds
    • Repetition time automatic mode 2, 5, 10, 15, 30, 60 minutes
    • Statistics mode Duration 5 minutes maternal non-invasive blood pressure
    • Cycle Time (Typical at HR 60 bpm) Auto / manual 35 seconds Stat 17 seconds, maximum 120 seconds
    • Setting alarms 5 mmHg limited steps, 10-245 mmHg diastolic, systolic 30-270 mmHg, overpressure safety limit of 300 mm Hg for more than 2 seconds
    • Frequency range measurable press Within the heart rate range 30 240 bpm, Averaged over the measurement of NIBP
    • Pulse oximetry and ECG Maternal Maternal Heart Rate Range 0 to 100%
    • BPM range 30 to 300 bpm
    • Accuracy ± 1%
    • Resolution 1 bpm
    • Pulse rate limit alarm range 70% – 90%, setting 1% steps
    • 1 standard deviation accuracy M1191A 70 to 100% ± 2.5%, M1192A 70 to 100% ± 2.5%, M1194A 70 to 100% ± 4%, 80% Nellcor sensors 100 ± 3%
    • heart rate measuring range 30 to 240 bpm, Accuracy ± 1 bpm, Recorder Resolution: 0.25 bpm, Display: 1 bpm
    • Alarm limits heart rate (excluding NIBP) Range 30 to 250 bpm, 5 BPM steps Adjustment
    • Digital display of maternal Two screen displays heart rate (orange) and a visualization of uterine activity (green). Type: (10mm) 7-segment LED

    maternal dispay

    • systolic measurement
    • diastolic measurement
    • SpO2 level
    • The maternal heart rate (derived from MECG Whether), the pulse frequency (derived from pulse oximetry Whether) or the average pulse frequency (derived from NIBP Whether)
    • Alarm status for each parameter (except the pulse frequency NIBP)
    • Warning message (if any)