GE Corometrics 170 Series Fetal Monitors

Whether you make a antepartum fetal monitoring in an office environment or in the hospital, Fetal Monitor Corometrics * 170 Series can help. You can rely on our fetal monitors to help Improve the standard of care for Their mothers waiting. Compact and lightweight design to help you These monitors care for effective and efficient way mom and baby through accurate monitoring and non-invasive baby’s heart rate stress test. The 170 series is used With our ultrasonic transducers Toco and 9-crystal Nautilus *, watertight and lightweight for convenient and reliable monitoring.
• Alert FHR problems – fetal heart rate alarm audible and visual alerts Provides if the heart rate is higher or lower than the normal range Set as
• It Helps to place the transducer – Facilitate independent volume controls for more effective transducer location supervision
• You can check multiple heart rates – There is an option to monitor twins
• Important information prominently displays – The large and easy to read LCD display presents information on fetal Cleary heart rate and uterine activity
• Offers portability – An optional mobile rolling cart Allows you to transport the monitor and all accessories Necessary

Description

Dimensions

• Height x Width x Depth: 14.6 x 42.5 x 25.4 cm (5.75 x 16.75 x 10 inches)
• Weight: 3.6 kg (8 pounds)

energy requirements

• Rated line voltage: 100-230 VAC
• 50/60 Hz line frequency (47-63 Hz Operates on)
• Power consumption: ≤ 30 VA
• Monitor DC Input 12 Vdc at 2.5A

Operating Specifications

• Pulsed Doppler processing Technical automatic correlation
• Transducer type 9-crystal
• 2 kHz pulse repetition (all modes)
• Frequency Pulse duration 92 microseconds
• 1151 MHz frequency transmitter
• Isata Temporary Space-Media <5 mW / cm2 • Medium intensity • Beam 20 dB focal area 16.6 cm2, range = 7 cm • instantaneous peak 1.8 mW / cm2 • Intensity • Heart rate range 50-210 BPM count • Leakage current Meets IEC standard 60 1.1 harmonized national and / or IEC 601.1.1; Meets EN 60601-1-2: 2002 fecG mode

• Technique: Peak Detect, cardiotachometer beat-to-beat
• Cardiac interval range: 30-240 BPM
• Heart rate resolution: 1 BPM
• Artifact Removal: selectable service ± 25 BPM artifact rejection
• Accounting signal range input: 15μV to 2 mV peak to peak
• Tolerance compensation voltage (differential): ± 300 mVdc maximum
• high common mode voltage: 20V peak to peak
• Common Mode Rejection: Balanced:> 120 dB at mains frequency, with patient cable 5kΩRA or LA:> 110 dB at

mains frequency

• Input Impedance: Differential:> 10MΩ; Common mode:> 20MΩ
• Mains frequency rejection:> 40 dB
• Leakage current: Meets the standard IEC 601.1 harmonized national and / or IEC 601.1.1
• Isolation network to Patient:> 5656 Vdc

Mode ultrasound

• Technique: Pulsed Doppler With autocorrelation process
• Transfer type transducer 9-crystal
• Pulse repetition frequency: 2 kHz (all modes)
• Pulse duration: 92 ms
• Transmitter Frequency: 1151 MHz
• Average space-temporal average intensity: Isata <5 mW / cm² • 20 dB beam focal area: 16.6 cm², range = 7 cm • maximum instantaneous intensity: 1.8 mW / cm² • Heart rate: 50-210 BPM • Leakage current: Meets the standard IEC 601.1 harmonized national and / or IEC 601.1.1