Description
Weight:
- 296 lbs (134.2 kg) (base unit without vaporizers or cylinders).
Dimensions:
- 40.7 x 52 x 33 “(103.5 x 132 x 84 cm) (WXHXD) (with padding and mounting Vaporizers 3).
Power supply:
- 100 – 240 VAC, 50/60 Hz, 2.3 max. (Not configurable).
Operation time:
- Up to 120 minutes, at Least 45 minutes. (With batteries fully charged.)
E-vent fan:
- Electronically controlled, electrically actuated.
Standard operating modes:
- Volume controlled ventilation manual ventilation, spontaneous breathing.
Options Operating modes:
- Pressure Controlled Ventilation, Pressure Support.
Breathing frequency:
- 4 to 60 1 / min.
Max. Minute volume (MV):
- 0 to 99.9 L / min.
Positive end-expiratory pressure:
- 0-20 cmH2O (PEEP).
Inspiratory / Forfeiture:
- 4: 1 to 1: 4 (TI: TE).
Pressure limitation:
- 15-70 cmH _ {2} O (PMAX).
Tidal volume (VT):
- 20-1400 mL in volume control.
Inspiratory pause (TIP: TI):
- 0 – 50%.
inspiratory pressure (PINSP):
- CmH2O PEEP + 5-65.
inspiratory flow (InspFlow) 1:
- 0-75 L / min in volume and pressure control.
- 10-85 L / min in pressure support.
Pressure support level (Δ PPS):
- PEEP + 3 to 20 cmH2O.
Apnea ventilation frequency min .:
- January 3 to 20 / min and “OFF” (Min Freq ..).
Trigger:
- 2-15 l / min.
Integrated safety functions:
- The Oxygen Ratio Controller Sensitive (S-ORC) Guarantees a minimum O2 concentration of 23% in a mixture of O2 / N2O.
- N2O if the fresh gas valve is closed O2 or O2 if the flow rate is less than 0.2 L / min.
- audible and visual indication (LED flashing red) if the O2 pressure falls below 0.9 bar (0.4 bar) ± 0.4 bar.
- In case of lack of electricity and battery manual ventilation, gas delivery and agent delivery is possible.
- The positive pressure relief valve opens to 75 ± 5 cmH2O.
- The negative pressure relief valve opens to – 7.5 to – 9 cmH2O.
Range of fresh gas flow indicators:
- 0.00 to 12.0 L / min.
Total fresh gas flow meter:
- 0 to 10 l / min, calibrated with a mixture of 50% O2 and 50% mixture of N20.
O2 flush:
- A 55 psi (3.8 kPa x 100): max. 50 l / min.
- A 50 psi (3.4 kPa x 100): max. 35 l / min.
Vaporizer assembly:
- Dr. ger mount automatic exclusion.
Control screen:
- 6.5 “(16.5cm) black / amber.
Supervision:
- Continuous monitoring of inspiratory O2 concentration, respiratory rate, tidal volume, minute volume, medium pressure or plateau, peak airway pressure and PEEP.
- In Addition, all fresh gas flow information is displayed as virtual flow tubes.
Serial interface:
- 1 x RS 232 (standard).
protocols:
- VitaLink and Medibus.
Data available for export:
- All fresh gas flow, ventilation and O2 data, flow and pressure in real time.
Volume of CO2 absorbed:
- 1.5 liters, Option: premixing Dräger CLIC Absorber (1.2 L).
Gas supply:
- O2, N2O and air.
Yokes cylinder:
- O2, N2O, air, yokes tip.
Additional accessories:
- Gas jet suction patient, strip output, additional O2 flow tube.
Volume of The entire system compact breathing:
- 1.7 liters + bag.