Drager Fabius OS

  • The family operation and design Ensure ease of use and a short learning curve.
  • RS 232 Enables Communication with automated recordkeeping systems to improve increase patient throughput.
  • Suitable compact breathing system (COZY).
  • Ventilates any patient, even When your needs change to Accommodate Sicker Patients With more complex procedures.
  • It does not consume gas drive, enabling a dramatic increase ventilation time and reduced cost.

Description

Weight:

  • 296 lbs (134.2 kg) (base unit without vaporizers or cylinders).

Dimensions:

  • 40.7 x 52 x 33 “(103.5 x 132 x 84 cm) (WXHXD) (with padding and mounting Vaporizers 3).

Power supply:

  • 100 – 240 VAC, 50/60 Hz, 2.3 max. (Not configurable).

Operation time:

  • Up to 120 minutes, at Least 45 minutes. (With batteries fully charged.)

E-vent fan:

  • Electronically controlled, electrically actuated.

Standard operating modes:

  • Volume controlled ventilation manual ventilation, spontaneous breathing.

Options Operating modes:

  • Pressure Controlled Ventilation, Pressure Support.

Breathing frequency:

  • 4 to 60 1 / min.

Max. Minute volume (MV):

  • 0 to 99.9 L / min.

Positive end-expiratory pressure:

  • 0-20 cmH2O (PEEP).

Inspiratory / Forfeiture:

  • 4: 1 to 1: 4 (TI: TE).

Pressure limitation:

  • 15-70 cmH _ {2} O (PMAX).

Tidal volume (VT):

  • 20-1400 mL in volume control.

Inspiratory pause (TIP: TI):

  • 0 – 50%.

inspiratory pressure (PINSP):

  • CmH2O PEEP + 5-65.

inspiratory flow (InspFlow) 1:

  • 0-75 L / min in volume and pressure control.
  • 10-85 L / min in pressure support.

Pressure support level (Δ PPS):

  • PEEP + 3 to 20 cmH2O.

Apnea ventilation frequency min .:

  • January 3 to 20 / min and “OFF” (Min Freq ..).

Trigger:

  • 2-15 l / min.

Integrated safety functions:

  • The Oxygen Ratio Controller Sensitive (S-ORC) Guarantees a minimum O2 concentration of 23% in a mixture of O2 / N2O.
  • N2O if the fresh gas valve is closed O2 or O2 if the flow rate is less than 0.2 L / min.
  • audible and visual indication (LED flashing red) if the O2 pressure falls below 0.9 bar (0.4 bar) ± 0.4 bar.
  • In case of lack of electricity and battery manual ventilation, gas delivery and agent delivery is possible.
  • The positive pressure relief valve opens to 75 ± 5 cmH2O.
  • The negative pressure relief valve opens to – 7.5 to – 9 cmH2O.

Range of fresh gas flow indicators:

  • 0.00 to 12.0 L / min.

Total fresh gas flow meter:

  • 0 to 10 l / min, calibrated with a mixture of 50% O2 and 50% mixture of N20.

O2 flush:

  • A 55 psi (3.8 kPa x 100): max. 50 l / min.
  • A 50 psi (3.4 kPa x 100): max. 35 l / min.

Vaporizer assembly:

  • Dr. ger mount automatic exclusion.

Control screen:

  • 6.5 “(16.5cm) black / amber.

Supervision:

  • Continuous monitoring of inspiratory O2 concentration, respiratory rate, tidal volume, minute volume, medium pressure or plateau, peak airway pressure and PEEP.
  • In Addition, all fresh gas flow information is displayed as virtual flow tubes.

Serial interface:

  • 1 x RS 232 (standard).

protocols:

  • VitaLink and Medibus.

Data available for export:

  • All fresh gas flow, ventilation and O2 data, flow and pressure in real time.

Volume of CO2 absorbed:

  • 1.5 liters, Option: premixing Dräger CLIC Absorber (1.2 L).

Gas supply:

  • O2, N2O and air.

Yokes cylinder:

  • O2, N2O, air, yokes tip.

Additional accessories:

  • Gas jet suction patient, strip output, additional O2 flow tube.

Volume of The entire system compact breathing:

  • 1.7 liters + bag.