B Braun Outlook 100ES

Equipped with a color-coded keypad and audible key clicks, the safe, reliable and easy to use Outlook® comprehensive 100GB infusion pump provides “at-a-glance” viewing of infusion status on a large colored display.

Designed to help PREVENT IV medication administration errors, the Outlook 100ES Safety Infusion Pump System’s extensive customizable drug library DoseGuard ™ Allows you to configure the pump to match your clinical practice.

  • Intuitive: A “brain” in each channel pump Helps Prevent confusion and catastrophic failures pump
  • Versatile: Vertical stacking Takes less space
  • + KeyGuard ™: Non-numeric keypad arrows to help Simple With Preventative Manual programming errors related to zero vs. decimal entry
  • Air Trapping Cassette: Catches up to 3 mLs of air helping to reduce nuisance air-in-line alarms
  • Proven delivery mechanism providing reliable and accurate operation
  • Real-time display of dose and limit values ​​for titration During infusion safety
  • Active matrix for alphabetic quick and easy drug selection
  • Loading Dose Bolus and On Demand configurations for all DoseGuard Drugs

Description

  • Height: 11.4 cm (4.5 in)
  • Depth: 22.2 cm (8.75 in)
  • Weight: 5 kg (11 lbs)

Power

  • Power: 120 VAC, 3A, 60 Hz
  • Grounding Resistance: Meets or Exceeds UL Standard 2601-1
  • Leakage Current: Meets or Exceeds UL Standard 2601-1

general

  • Mechanism: Positive Displacement Pressure Reservoir
  • UL Certified: Yes. Meets or Exceeds 2601-1, IPX1 drip rating
  • Battery: 12V NiMH
  • Battery Operating Time: 7 hours at 25 ml / hr
  • Rate Range: 0.1 to 999.9 mL / hr in 0.1 mL increments
  • Micro Mode: 0.1 to 99.9 ml / hr in 0.1 mL increments
  • Volume to be Delivered Range: 0.1 to 9999.9 mL in 0.1 mL increments
  • Occlusion Pressure: Adjustable Settings: 75, 100, 200, 300, 400, 500, and 750 mmHg
  • KVO Rate: 3 mL / hr or lower is selected whichever rate
  • Volumetric Accuracy: ± 5%
  • Alarms: Air-in-line, Hold Time Exceeded, Low Battery Warning, Plug In Alarm, DoseGuard ™ Alert, RateGuard ™ Alert, Downstream Occlusion, Check Set, Bag Empty, Upstream Occlusion, System Error
  • Tubing: Pump Sets Horizon®
  • Modes / Features: DOSE Mode With DoseGuard ™ Drug Library, Primary and Piggyback Modes With RateGuard ™ Solution Library, Loading Dose and On-demand Bolus modes, Profile Mode, Program Mode, Set Time and Volume, Schedule Next Run, Micro Mode, q (x) Mode, Mode Epidural
  • Configuraton Custom Software: Outlook® ES Pump Configuration Editor Software (Required-One time fee, unlimited use license)