Philips Avalon CTS M1351a

The Avalon Cordless Transducer System (CTS) Helps Transform and delivery work, offering mothers and care teams the flexibility They Want, Allowing fetal and maternal continuous monitoring and comfortable With exceptional mobility. Avalon CTS Helps Provide a consistent and clear picture of the condition of the patient to trust the decision making.
• Transducer wireless play: uterine activity externally Measured
• The ultrasound transducer wireless fetal heart rate Measures and movement
• Identifier bed: the transducers matches based stations and each bed
• The base station Receives the transducer signals: transducers and recharges the PLUGGED
• The plug-and-play design transducer With automatic screen, in combination With Philips fetal monitors, Allows focus on patient care, not the system
• Status indicators shows how Transducer Clearly the system works at all times
• Position indicator slot: Helps Ensure That each transducer returns to ITS correct position
• Transducer wireless ECG or ECG Measured fetal ECG direct maternal
• Battery indicator displays the state of charge (batteries work 16 hours at Least

Description

Philips Avalon CTS M1351a Specifications

Base dimensions

• Size mm / (in): width x depth x height 350 x 240 x 75 (13.8 x 9.5 x 3.0 in)
• Weight 2.5kg / 5.5 lbs without transducers

Transducer Dimensions

• Size (diameter) <10 cm / 3.94 in • Weight <140 g / 4.8 oz Power

• Supply voltage 100 VAC to 240 VAC ± 10%
• Supply frequency range 50 Hz to 60 Hz
• Consumption 15 VA

Base station

• Type of protection against electric shock: Class I Equipment
• -110 dBm Input Sensitivity Input Sensitivity @ 30dB Signal to Noise Ratio
• Rejected image rejection Image> 80dB
• Ranges
o Reception range (line of sight) about 100 m / 300 ft
• Antenna Input impedance 50 Ω
• Ingress Protection code IP X1 Water (only protection against drops of water falling vertically)

monitor interface

• Toco Departure
o Accuracy ± 0.5% per 100 mmHg (without the transmitter included)
o Offset ± 5 Drives (without the transmitter included)
o Range 0 to 4V
• Voltage range
o US 4mVpp voltage range to 4Vpp
o ECG voltage range 0.1Vpp to 4Vpp

Battery

• Type Lithium Ion
• Capacity> 16 hours (> 700mAh)
• Life> 500 charging cycles / discharge (new battery at 25 ° C / 77 ° F)
• Transducer storage time
o ≥ 1 year at 25 ° C / 77 ° F (full battery)
o ≥ 1 month at 25 ° C / 77 ° F (empty battery)
• Recharge time
o 100% load <3 h o ≤ 66% loaded 1h • Forced discharge current approx. 45mA • Leakage current discharge stop @ Vbat = 3 V, 25 ° C 20 uA (typical) 70 uA (max) RF unit
• -12 dBm rated output RF ± 6 dB ERP
• See Carrier Frequency Range Frequency Bands
• minimum frequency of the frequency range 10 MHz option
• 25kHz channel spacing of 12.5kHz or

General Specifications Transducer

• Shock resistance Withstands 1m drop in the concrete surface With cosmetic damage possible
• Underwater usability 0.5m / 1.64 ft
• Code input protection IP 68 water (dip 0.5 m / 1.64 ft for 5 hours)

Environmental

• Temperature range
o Charging 0 ° C to 45 ° C (32 ° F to 113 ° F)
o Operation 0 ° C to 45 ° C (32 ° F to 113 ° F)
o Storage (battery) -20 ° C to + 60 ° C (-4 ° F to 158 ° F)
o Storage battery depends on the level of initial charge and temperature (shelf life at high temperatures Significantly Decreases (> 45 ° C / 113 ° F)
• humidity range
o Operation 5% to 95% RH @ 40 ° C / 104 ° F
o Storage 5% to 85% RH @ 50 ° C / 122 ° F
• Altitude range
o Operating ≤ 3000m / 9800 feet
o Storage ≤ 15000m / 49000 ft