Description
Weight
- Basic vacuum container: 75.4 lbs. / 34.2 kg
- Container loaded or configured: 198 lbs. / 91 kg
Dimensions W x D x L
- Container: (W) x 30.11 inches (H) x 30.16 inches (D) 30.11 inches
- Fabius kick M installation in the container: (W) x 49.8 inches (H) x 47.2 inches (D) 31.9 in.
Environmental conditions
- Operating temperature: 10-35 ° C (50-95 ° F)
- Storage temperature: 14-140 ° F (-10 to 60 ° C)
- Power supply (not configurable classification): 100 to 240 VAC, 50/60 Hz, 70 VA
- Battery (supports fan and integrated monitor): > 45 min
- Operating modes: Standard: Manual / spontaneous; Volume control (VC); Pressure Control (PC); pressure; Support (PS); Structuralizado Volume Control; PS ventilation (SIMV / PS)
- Breathing frequency: 4 to 60 bpm
- Positive end expiratory pressure (PEEP) 0-20 cmH2O
- Inspiratory / expiratory (Ti: I): 4: 1 to 1: 4
- Pressure limit (Pmax): 15 to 70 cmH2O
- Tidal volume (VT): 20-1400 mL in volume control; 20-1100 ml SIMV / PS
- Inspiratory pause (Tip: Ti): 0-50%
- SIMV inspiratory time (Tinsp): 0.3 to 4.0 s
- Inspiratory Pressure (Pinsp): (PEEP + 5) to 65 cmH2O
- Inspiratory flow (InspFlow): 10 to 75 L / min in volume; And pressure control; 10 to 85 L / min in pressure support
- Pressure support level (ΔPPS): PEEP +3 to 20 cmH2O
- Min Ventilation frequency-apnea (Freq min … ): 3 to 20 bpm and “OFF”
- Trigger: 2 to 15 L / min
- Integrated safety: The ratio controller oxygen sensitive (S-ORC) Guarantees a minimum O2 concentration of 23% in a mixture of O2 / N2O. N2O if the fresh gas valve is closed O2 or O2 if the flow rate is less than 0.2 L / min. Audible and visual indication (flashing LED network) if the O2 pressure drops below 20 psi (1.38 bar) ± 0.9 bar (4 psi). In case of lack of electricity and battery manual ventilation, gas delivery and agent delivery is possible. The positive pressure relief valve opens to 75 ± 5 cmH2O. The negative pressure relief valve opens -7.5 to -9 cmH2O.
- Range of fresh gas flow indicators: 0.00 to 12.0 L / min
- Total fresh gas flow meter: 0 to 10 l / min, calibrated with a mixture of 50% O2 and 50% N2O mixing
- O2 (bypass) to 55 psi (3.8 kPa x 100): max. 50 l / min; A 50 psi (3.4 kPa x 100): max. 35 l / min
- Vaporizer assembly: position 1 Mounting Dräger
- Monitoring: Monitoring continuous inspiratory O2 concentration, respiratory rate, tidal volume, minute volume, medium pressure or plateau, peak airway pressure and PEEP. In Addition, all fresh gas flow information is displayed as virtual flow tubes.
- Serial Interface: 1 x RS 232 (standard)
- Protocols: VitaLink and Medibus
- Data available for export: All data flow, ventilation and O2 fresh gas flow curves and pressure curves
- Absorb CO2 volume: 1.5 liters, Option: Dräger precharged CLIC Absorber
- Volume of the Entire compact breathing system: 2.8 liter bag +